R-value is the term given to thermal resistance to heat flow. The higher the R-value of an insulation product, the more effective the insulation properties. Spray polyurethane foam comes in a range of densities and cel structure. Low density foams are referred to as Open Cel SPF while higher density foams are referred to as Closed Cel foam. 1.8-2 pound polyurethane foam has the highest R-value of readily available spray foam insulation used in homes and buildings.[4]
We have a 22 year old home located in southeastern georgia where the humidity is very high. In the past 2 weeks our floors have started buckling all over. We have a vented crawl space and the old insulation is drooping from moisture and the wood is wet. We are debating between the "encapulation" method or the spray foam method to repair this issue. Which would you recommend? https://www.youtube.com/attribution_link?a=ggLAUsiuI_o&u=watch?v=XXXXXX&feature=share

The process by which heat energy in the form of light (usually IR unless the substrate is hot enough to glow in the visible range) is emitted more strongly by warm surfaces and absorbed by other materials especially those of low IR reflectivity (think matte black finish). Radiant heat transfer does not require a medium. Foam insulation materials, such as spray foam insulation, are opaque to thermal radiation, like most solid materials. http://www.youtube.com/v/ggLAUsiuI_o
I've seen this only once, and it was with closed cell foam, but I've heard of it happening with open cell foam, too. I don't know the details, but I've heard it could result from a bad batch of chemicals, improper mixing, or too high a temperature. Whatever the cause, it's not a good thing. The photo below shows how the spray foam pulled away from the studs. A little bit of uninsulated area like that adds up to a lot of heat loss/gain when the whole house has that problem, as it did here.

How Much For Spray Foam


One thing I wanted to mention was that I think your price point is a little high and that might deter people from considering spray foam. As a project manager for a spray foam company for years I can tell you that we offer 0.5 Lb. open-cell foam at around $.25/board foot. We even offer a 1.0 Lb. open-cell foam for less/the same cost as you quoted the 0.5 Lb. foam for above. The 1/0 Lb. open-cell foam has an R-value of almost 5.


This is more common with closed cell foam, but it happens with open cell foam, too. Since closed cell foam has a higher R-value per inch, installers generally spray 2" in walls and 3" in rooflines to meet the energy code requirements of R-13 and R-19, respectively. (I'm not going to dive into the energy code here, but these numbers apply to many climate zones, the latter being allowed under the UA tradeoffs rule. See the Energy Nerd's blog on this topic if you want to argue.)
However, coating asphalt shingles and built-up composition roofs requires more caution. The National Roofing Contractors Association’s (NRCA) director of technical services has stated "The roofing industry is aware of a number of issues that could have negative consequences for field application of coatings over asphalt shingle roof systems. Anyone considering this type of application should be aware of the concerns so they can weigh them against the benefits claimed in coating product promotional materials."[2]

Spray foam insulation is a great product. Homes insulated with it can be some of the most efficient and comfortable homes built. I've been in plenty of these homes and can tell you that when spray foam is installed properly, they outperform 99% of fiberglass batt-insulated, stick-built homes. (I can also tell you that 73% of all statistics are made up on the spot, so please don't ask for documentation of that statistic.)
This tropic heat actually is the cause that the steel structure, which most roofs in that part of the world are built on, expands and contracts all the time. By doing so, the sun-battered steel structure causes the roof tiles to dislodge and slowly creates small openings between the roof tiles, through which rain water can run into, creating leaks that can cause much damage to plastered ceilings and electric wiring.
Typical roof coating dry film thickness vary from paint film thickness (plus or minus 3 dry mils) to more than 40 dry mils. This means a roof coating actually becomes the top layer of a composite roof membrane and underlying system. As such, the roof coating is the topmost layer of protection for the membrane, receiving the impact of sunlight (both infrared and ultraviolet (UV), rain, hail and physical damage.
Apply coating when the roof is dry and the sealant has set. You will be using a 9-inch heavy-duty frame, ½-inch paint roller for spreading coating on roof or 1-1/4-inch roller for dipping in pail, and a 5–to-6-foot extension pole. Use a 3/4-inch roller with basecoats and emulsions. Map out your roof and make each pail fill that area. See Elastek Product Sheets for recommended coverage. An inexpensive 3-inch or 4-inch brush should be used to reach areas not possible with a roller. Use a stiff paintbrush for applying 103 Crack & Joint Sealant.
RetroFoam of Michigan has more than 15 years of experience insulating thousands of homes and pole barns across the lower peninsula. We hear a lot of misconceptions about foam insulation and work to make sure we clear up any wrong ideas about foam insulation. Our staff helped us put together this list of misconceptions adding their insights to dispel any misinformation.