Heat which is created elsewhere that is transported by means of a fluid, such as water or in our case air. Spray foam insulation's most important attribute is the ability to air seal creating a custom airtight envelope within the building structure. The added benefit to air sealing is the ability to block convective heat transfer from interior to exterior during heating months and vice versa during cooling months, as the heat cannot escape through gaps in the buildings envelope without the aid of air movement from infiltration as a means of transport.

Spray Foam Attic Insulation


There are two main types of spray foam to consider: open-cell and closed-cell. Open-cell spray foam has a lower R-value per inch and because of this, typically a lower price tag. The soft, low-density material is used for interior applications. Its high permeability allows for moisture to pass through, which contributes to bi-directional drying of the assembly, but it may not be ideal for all applications or climates. 
SPF insulation applied by professionals is usually described as either a high- or low-pressure foam and is available as either open- or closed-cell. Each type has advantages and disadvantages depending on the application requirements. The comparison chart below can be helpful in explaining or understanding which type of SPF insulation is best suited to a specific application.
Allison--would be very interested in your take on the GHG issues of foams, which have received lots of smart commentary recently. To highlight a few: architect Jesse Thompson's comments on Tom's Good vs Bad post on Energy Circle, the very thorough piece by Alex Wilson on Green Building Advisor and Michael Anschel's cautionary diatribe on Remodeling. 
A: The RV roof coating works by waterproofing, weatherproofing and sealing our RV roofs from elements, including rain, snow, wind and other outer forces. It can also resist impact from leaves, twigs, dusts and other things that would otherwise damage the roof. It also works by reflecting UV rays, keeping the roof from degradation. The roof coating can also prevent leaks, heating and cooling loss and discomfort in our RV.
My other question was gonna be this. We ripped all the drywall out after Hurricane Harvey and we found some latent termite damage from some time back. One of the common studs in one corner is pretty well eaten to shreds. I was gonna brace it but then I read about more modern framing practices and I read how each stud is a thermal bridge. So now I'm thinking that I won't bother with it because the house hasn't fallen down and the foam might help a little. Unless you say to brace the stud. Then I'll do it, Martin! :)
We are turning our roof into an unvented roof assembly by raising the roof and blowing in SPF. We are planning to leave the existing vapor barrier down but remove the fiberglass batting and then adding 6" of SPF in all the cavities, to completely seal and insulate the house. Should we have any concerns about doing it "upside down" and not spraying the foam directly to the underside/sheathing of the roof?

Spray Foam Garage


In the early days of insulating attics, people believed the insulation was a heat source. That’s not the case, as the insulation is actually a barrier between two areas of different temperatures. As for the “hot roof” theory, the unvented attic system could make the temperature of the roof go up a little, but this increase won’t cause damage to your shingles.

Steve: If your spray foam installer leaves the vents open, he will be committing the 2nd of the 4 problems I described above. You will most likely have comfort and efficiency problems. You may well have condensation problems. You will be spending a lot of money on a product that likely won't perform as it should. Don't let him leave the vents open. If the installer you've chosen doesn't understand this, you may want to choose someone else. 
In the early days of insulating attics, people believed the insulation was a heat source. That’s not the case, as the insulation is actually a barrier between two areas of different temperatures. As for the “hot roof” theory, the unvented attic system could make the temperature of the roof go up a little, but this increase won’t cause damage to your shingles.
Spray foam insulation, when properly installed is both an air barrier and when closed cell foam is used at the proper depth a vapor barrier!  Before hiring any contractor you should establish the brand of foam being used and verify that with the named manufacture.  Please ask for ESR reports and MSDS sheets on any foam being installed in your home. A couple areas where you might consider spray foam insulation include: http://www.youtube.com/v/ggLAUsiuI_o&feature=youtube_gdata

The complete line of JM open- and closed-cell spray foam insulation solutions provide superior thermal and energy performance, as well as advanced air, moisture and sound control in any climate. These products can be used in interior and exterior walls, unvented and vented attics, floors, ceilings and crawl spaces. Plus, using spray foam can reduce air leaks and create a more comfortable, energy-efficient home – meaning you could see more energy savings every month.


Repair and seal roof penetrations, tears, open seams, etc. using Elastek 103 Crack & Joint Sealant and reinforce with polyester roof fabric as necessary. In larger or deep ponding areas, apply Elastek 500 Puddle Plaster to fill in areas that hold water. Avoid using plastic roof cement. Serious ponding should be referred to a roofing contractor. Blisters in previous coatings may be opened but these areas must be allowed to dry-out completely. Blisters in the roofing ply should be left alone unless likely to break. Caulk and reinforce open seams, roof penetrations, cracks, and tears. These are potential leak points so work carefully and thoroughly. Use fabric to build flashings around roof edges or roof penetrations, and to reinforce various coating repairs. A polyester fabric is used because it will stretch with the coatings. (Fiberglas fabric is not recommended.) Fabric is normally cut to extend three inches beyond the repaired area in all directions. The coating is applied to the roof surface and the fabric is immediately pushed into the wet surface. An additional coat is applied over the fabric and the patch is allowed to dry. If your roof has stucco parapets, examine them for cracks along the sides and top. These areas often permit water to enter the wall and can cause blisters and wrinkles in the roof surface. Repair with Elastek 103 Crack & Joint Sealant. If you do not have parapets, examine the metal drip edge for a tight seal with the roof membrane. Use 4″ or 6″ roofing fabric covered under and over with Crack & Joint Sealant to seal cracks along drip edges, penetrations, and open seams.

Most closed-cell spray foam is now formed using hydrofluorocarbon (HFC) blowing agents that have high global warming potential, partially or completely offsetting the climate benefits of the energy savings they can offer. In the United States, HFCs are scheduled to be phased out by January, 2021. A few spray foam suppliers have started supplying spray foam blown with hydrofluoroolefin (HFO) blowing agents without this problem as of early 2017.[14]

RetroFoam of Michigan has more than 15 years of experience insulating thousands of homes and pole barns across the lower peninsula. We hear a lot of misconceptions about foam insulation and work to make sure we clear up any wrong ideas about foam insulation. Our staff helped us put together this list of misconceptions adding their insights to dispel any misinformation.

R-value, the thermal resistance measure of insulation, varies between all insulation products whether they are fiberglass, cellulose, open-cell spray foam insulation or closed-cell sprayed-in foam insulation. Generally speaking the rule of thumb is the higher the R-value, the greater the insulating power.  Focusing on spray foam insulation materials, there is a difference between the two main types. According to industry publication, Fine Home Building, the R-value for open-cell spray foam is between R-3.5 – R-3.6 per inch. However, there are open-cell spray foam insulation products actually offer R-3.7 per inch such as Icynene Classic and Icynene Classic Max. The open cell structure of low density foam insulation means the R-value is lower than its closed-cell counterpart. Nevertheless, open-cell spray foam does offer superior and consistent thermal insulation and air sealing properties.
Fill and seal expanding foam sealant is urethane Fill and seal expanding foam sealant is urethane foam designed to fill large areas quickly and permanently. Uses include filling holes cracks or gaps that require a complete airtight and waterproof seal but are too large to be filled with ordinary caulk. The foam expands approximately 3 times its original ...  More + Product Details Close http://youtube.com/watch?feature=youtube_gdata&v=ggLAUsiuI_o

The product is an acrylic coating, which is packed conveniently for ease of use. As it is also in one-gallon size, you can rely on its supreme area coverage reaching up to 125 square feet. The Dicor rubber roof coating is also very easy to apply. When shopping around for a roof coating, we believe it pays off to find an easy to apply product for fast results. It is one of the best qualities of the RV roof coating that makes it a top pick in the category.

Roof Coating

×