Warning: EnergyGuard™ Elastomeric Roof Coatings can freeze below 32° F. This is because the product is water based. In case of freezing temperatures, stop the application process. After application, you must allow the product time to dry before exposing the elastomeric roof coating to foot traffic or water. You should also cover the containers and dispose them responsibly after application. In case you or someone else i.e. a child ingests the coating seek immediate medical attention. Don't induce vomiting.
SPF, a spray-applied cellular plastic, is made by mixing chemicals to create foam. Those chemicals react very quickly, expanding on contact to create foam that insulates, air seals and provides a moisture barrier. When properly installed, SPF forms a continuous barrier on walls, around corners and on contoured surfaces. It resists heat transfer very well and is an effective solution for reducing unwanted air infiltration through cracks, seams, and joints. http://youtube.com/v/ggLAUsiuI_o

Empire Spray Foam is conveniently located in North Texas and proudly serves the Tarrant, Dallas, Denton, Wise, Parker, Hood, Johnson, Ellis, Kaufman, Rockwall, and Collin Counties with high quality spray foam and coatings designed to meet the needs of homeowners and businesses. Whether you are looking for energy savings, structural reinforcement, or weatherproofing, we have the solution. Call today to discuss your spray polyurethane foam options 817-516-2014.
Open-cell is also known as half-pound foam. It has an R-Value of 3.5-3.6 per inch, and its density is bout 0.5 pounds per cubic food. Low-density foams like these are made partially from raw biological materials Carbon dioxide or water is also used in the makeup. Open-cell uses far less material than closed-cell, but its R-Value is lower. Also, open cell requires a vapor retarder (like gypsum wallboard) and is riskier when used for roof sheathing. It's not highly recommended that you use open-cell insulation if you live in a cold climate unless you have that extra barrier. You should also compare how much money you spend versus how effective the open-cell insulation is wherever it's installed.

Spray Foam Cost


Steve: If your spray foam installer leaves the vents open, he will be committing the 2nd of the 4 problems I described above. You will most likely have comfort and efficiency problems. You may well have condensation problems. You will be spending a lot of money on a product that likely won't perform as it should. Don't let him leave the vents open. If the installer you've chosen doesn't understand this, you may want to choose someone else. 
There is a significant price difference when it comes to using foam insulation to insulate a new versus older home. Spraying insulation inside a newly constructed home is easier because the installation company can ensure the insulation will work effectively and design it for optimum defense against sound, heat transfer and utility costs. Installing spray foam in older homes that contain existing insulation can cost additional time and money -- it is not usually recommended as compared to weatherization or an energy aduit.

Spray Foam Near Me


Whether you’re sending something fragile in the mail or keeping valuables safe during a move, secure packing is everything. To protect a delicate item, simply fill a spare shopping bag half-full with spray insulation foam and place in the bottom of a box, pressing the item gently into the bag as it hardens to cushion the item. Repeat for the top and you have a DIY custom packaging solution that can handle the rigors of delivery.
In the early days of insulating attics, people believed the insulation was a heat source. That’s not the case, as the insulation is actually a barrier between two areas of different temperatures. As for the “hot roof” theory, the unvented attic system could make the temperature of the roof go up a little, but this increase won’t cause damage to your shingles.
Loctite TITE FOAM Window and Door is a Loctite TITE FOAM Window and Door is a new generation of polyurethane-based insulating foam sealant that expands to fill seal and insulate around window and door jambs. Loctite TITE FOAM is a minimal-expanding foam based on purified and concentrated ingredients that provides four times more density versus conventional window and ...  More + Product Details Close

a) Make sure that your house has been well heated prior to installation because the foam expands at different rates as it hits surfaces with different temperatures. If it is cold outside the sheathing may be much colder than the studs consequently the foam may expand more from the sides of the wall cavity creating air pockets in the wall cavity. This can be minimized by an experienced installer.

Spray Foam Tanks


If you’re not familiar, spray foam is a type of insulation that expands after you spray. The foam expands and seals, avoiding any type of unnecessary moisture (which can create mold) or encouraging pests to eat through your walls. It protects the lining of your house, and even can protect the heating and cooling of your house during those unbearably cold or hot days. https://youtube.com/watch?v=ggLAUsiuI_o
Also, I'm wondering... Is this website is being regularly updated? A local installer (in Oct, 2010) in MA quoted over twice the price you list here. "Open cell alone ~$1.35 per sq ft for R-13. Or a 'hybrid method' using 2inch closed cell for R-13 followed by 1.5inch open cell for R-6. Hybrid is $2.85 per sq foot for R-19 rating". Maybe installers are charging higher prices to profit from those trying to meet government energy rebate by Dec 31?
I have been looking to have closed cell insulation added through out my attic space. I cant seam to find a installed that wants to install no more than 2 inches, and thats not near my R-valve for South Carolina (Lake Greenwood)please send any advice that will help me to see what installer will perform the correct job. This is a expense that i can only afford to do once. Sandi 

Spray Foam Garage Ceiling


We love the Heng’s rubber roof coating because it is versatile enough to work on the RV roof and protects it from the elements longer than other products do. Plus, it is useful enough to be used in sealing seams and tears. Versatility does matter when shopping around for an RV roof coating. It ensures more uses, meaning more value for the money. That said we don’t need to buy a separate product to perform the tasks.
Sean, thanks for jumping in and answering John's questions. About choosing the right foam, I intentionally avoided the open cell vs. closed cell foam debate. I did this partly because it's worthy of an article all by itself, but mainly I didn't include it because, despite all the warnings the two sides issue about the other, I've never personally seen a problem caused by using open cell where they should've used closed cell or vice versa. I'm sure things like that happen; I just haven't seen it yet.
Thank you, Allison. We have a split system unit (actually 5) with the heat being propane. The foam guy said that it needed ventilation, so completely sealing the attic wouldn't be a good idea. It sounds like you are saying that the systems need to be vented out of the attic or replaced with some type of closed system. But I shouldn't bother spraying if the plan is to leave the soffet vents open. Is that correct?
Most flat roofs are not perfectly sloped, causing water to puddle in some areas, in particular around the drains and scuppers. Many roof coatings are not rated or warranted for "ponding water", and thus might fail pre-maturely if exposed to standing water over long periods of time. Serious consideration should be given to the performance and limitations of the coating being selected. Some manufacturers will warranty their coatings including ponding water. Typically, manufacturers for acrylic roof coatings do not include warranties for ponding water, while some polyurethane and silicone roof coatings manufacturers will. https://youtube.com/embed/ggLAUsiuI_o

A. You can use closed-cell spray foam that way if you want, although you should realize that the spray foam will prevent the roof sheathing from drying inward. This approach should only be used if the roof sheathing is bone dry, because it will never dry when sandwiched in this manner. Most building scientists would prefer to see fiberglass rather than closed-cell spray foam under the roof sheathing in this type of assembly.

Roof Coating Seal

×