Note: The practice of foam insulating the attic has raised eyebrows in the building industry because "standard" roofing techniques call for the attic to be ventilated; however, in a vented attic situation it will become approximately 130 degrees in the summer. There's no reason for an air-conditioning and vent-ductwork to have to work in that type of severe conditions. By applying Icynene right on the underside of the roof deck, the severe temperatures no longer exist in the attic. In short, the attic is now a "conditioned" space of the house that is just as comfortable as any other room in the home. This is called a "Compact Roof", which means you can frame right up against it. The one drawback of using expanded foam on the inside of the roof is that this will cause the temperature of the shingles to rise, but how much is not yet known. And how much damage a rise in temperatures could cause is debatable.
Part of that guidance will be explaining that interior, two component foam is applied with the professional using specific personal protective equipment (high-pressure foam is installed while using a respirator, for example). It is encouraged that professionals explain clearly to customers that this equipment, coupled with certain work and engineering practices, including ventilation, is used to minimize exposures to the chemicals used to make SPF during the job. http://www.youtube.com/e/ggLAUsiuI_o
Sealection® 500 has been Demilec's flagship product for more than 20 years, and has positioned Demilec as an industry-leading spray foam insulation manufacturer. As an environmentally-friendly product, it delivers superior performance, energy savings, and is an excellent return on investment for architects, builders, contractors, and homeowners, making it the ideal choice for insulation.
Roof coatings made with acrylics, urethanes or asphalt soften under the stress of ponding water or snowpack. Eventually, these roof coatings will bubble and peel away from the substrate, leaving your roof vulnerable to leaks, rot, and decay. However, GacoRoof’s 100% silicone formulation is designed to stand up to whatever the elements dish out. Silicone will withstand areas of ponding water without softening, bubbling or peeling from the substrate. Acrylic, urethane and asphalt roof coatings decompose and wear away from the stress of harsh sunlight, UV rays, and freeze-thaw cycles.

How Much Is Spray Foam Insulation Installation


I used this product to seal and insulate my rim joists as I am finishing the basement. The builder used R13 batt insulation when we built the house 3 years ago. I use a dehumidifier to control moisture in the basement which is below grade. The setting I use is 55%. The dehumidifier kicks on periodically and requires emptying every few days. Since using the foam all around the house on the rim joists and sill plate, the dehumidifier has stayed at 50% for over two weeks since spraying and rarely turns on anymore. I also put the original R13 batt insulation back up after the foam cured.
JM Corbond® Open-Cell Appendix X Spray Foam is a lower-density, nonstructural foam that offers most of the thermal performance and installation benefits of closed-cell spray foam at a lower cost. It provides an exceptional air and sound barrier as well as R-value, and meets AC 377 NFPA 286 Appendix X requirements for application without an ignition barrier in attics and crawl spaces. http://www.youtube.com/watch?v=ggLAUsiuI_o&feature=youtube_gdata
A: The RV roof coating works by waterproofing, weatherproofing and sealing our RV roofs from elements, including rain, snow, wind and other outer forces. It can also resist impact from leaves, twigs, dusts and other things that would otherwise damage the roof. It also works by reflecting UV rays, keeping the roof from degradation. The roof coating can also prevent leaks, heating and cooling loss and discomfort in our RV.

I've seen this only once, and it was with closed cell foam, but I've heard of it happening with open cell foam, too. I don't know the details, but I've heard it could result from a bad batch of chemicals, improper mixing, or too high a temperature. Whatever the cause, it's not a good thing. The photo below shows how the spray foam pulled away from the studs. A little bit of uninsulated area like that adds up to a lot of heat loss/gain when the whole house has that problem, as it did here.

How Much To Spray Foam Crawl Space


Roof coatings can add 25 years to the service life of a roof and reduce the amount of discarded roofing materials that end up in landfills. The infrared image on the right shows 175 °F (79 °C) on the uncoated (black) section of the modified bitumen roof. The coated (white) section is 79 °F (26 °C). Field studies have shown that cool roof coatings can lower rooftop temperatures and reduce air conditioning bills.

I started using Gaco years ago primarily to solve ponding water Problem. It has work well, solved my problems with other roofing options and repairs as well as many other Flat roof issues.  My only problems were experienced when I did not clean the surface well enough for good adhesion.  Follow the Instructions.  Great product and highly recommended. .

We live in middle TN and had our house foamed last year. We noticed recently that some of the foam was shrinking and seperating from the floor joists. We contacted the installer and he informed us that the manufacturer had a problem with a batch of foam during the time frame we had our house sprayed. The contractor wasn't sure if we had the recalled batch installed in our house or not. He said he would check the batch numbers and let us know. He seems like a nice guy promising to do whatever it takes to fix any problems. Do we trust him, however, to be truthful about the batch number? Do we have any options for finding out the information ourselves? I inspected the entire crawl space of the house and noticed approximately (5) areas that were seperating and a couple areas where the foam didn't adhere to the block. Do I assume by it being so infrequent that it is nothing to be concerned about? My concern is the walls that are not capable of being visually inspected because of sheetrock.
I started using Gaco years ago primarily to solve ponding water Problem. It has work well, solved my problems with other roofing options and repairs as well as many other Flat roof issues.  My only problems were experienced when I did not clean the surface well enough for good adhesion.  Follow the Instructions.  Great product and highly recommended. . http://www.youtube.com/v/ggLAUsiuI_o&feature=kp
R-value, the thermal resistance measure of insulation, varies between all insulation products whether they are fiberglass, cellulose, open-cell spray foam insulation or closed-cell sprayed-in foam insulation. Generally speaking the rule of thumb is the higher the R-value, the greater the insulating power.  Focusing on spray foam insulation materials, there is a difference between the two main types. According to industry publication, Fine Home Building, the R-value for open-cell spray foam is between R-3.5 – R-3.6 per inch. However, there are open-cell spray foam insulation products actually offer R-3.7 per inch such as Icynene Classic and Icynene Classic Max. The open cell structure of low density foam insulation means the R-value is lower than its closed-cell counterpart. Nevertheless, open-cell spray foam does offer superior and consistent thermal insulation and air sealing properties.
Roof Coatings should not be confused with deck coatings. Deck coatings are traffic bearing - designed for waterproofing areas where pedestrian (and in some cases vehicular) traffic is expected. Roof coatings will only waterproof the substrates but will not withstand any kind of on going use by people or vehicles (such as walkways, patios, sundecks, restaurants, etc.). http://m.youtube.com/watch?feature=player_embedded&v=ggLAUsiuI_o

JM Corbond® Open-Cell Appendix X Spray Foam is a lower-density, nonstructural foam that offers most of the thermal performance and installation benefits of closed-cell spray foam at a lower cost. It provides an exceptional air and sound barrier as well as R-value, and meets AC 377 NFPA 286 Appendix X requirements for application without an ignition barrier in attics and crawl spaces.


Installing spray foam is easy to do and can dramatically improve a building or home’s energy efficiency and thermal resistance. Our closed cell foam is so efficient just 3 inches of foam appled inside of wall cavities provides an insulation value of over R18!. Our products are specially formulated for both new construction and existing homes and buildings. https://www.youtube.com/watch?v=ggLAUsiuI_o&feature=youtu.be
Most closed-cell spray foam is now formed using hydrofluorocarbon (HFC) blowing agents that have high global warming potential, partially or completely offsetting the climate benefits of the energy savings they can offer. In the United States, HFCs are scheduled to be phased out by January, 2021. A few spray foam suppliers have started supplying spray foam blown with hydrofluoroolefin (HFO) blowing agents without this problem as of early 2017.[14] https://m.youtube.com/embed/ggLAUsiuI_o

I don't even want to ask this question but... several years ago we hired a local contractor to spray high density foam on the roof deck and walls of our unfinished 2nd floor. We realized that the job was done poorly and cut an access into the attic space to assess things. We realize now that they spray foamed directly to the chimney (no flashing). The chimney is currently used for a woodstove and DHW venting. The DHW will go away but wood stove will remain. My question is, how bad (unsafe) is this? I have found information on foam exposure to fire but have not been able to find anything about temperature ratings in general (i.e. what happens on prolonged exposure to high temperatures). http://www.youtube.com/e/ggLAUsiuI_o?app=desktop


Also, I'm wondering... Is this website is being regularly updated? A local installer (in Oct, 2010) in MA quoted over twice the price you list here. "Open cell alone ~$1.35 per sq ft for R-13. Or a 'hybrid method' using 2inch closed cell for R-13 followed by 1.5inch open cell for R-6. Hybrid is $2.85 per sq foot for R-19 rating". Maybe installers are charging higher prices to profit from those trying to meet government energy rebate by Dec 31?

Spray Foam Walls


I have to insulate my walls at the end of this week. That does not give me time to procure slow-rise foam, so my stud cavities will be filled with foam before I'm ready to fill the corner voids. I will not be able to drill straight through the corner studs. Instead, I will have to remove material where the studs meet. What sort of tool do you envisioning me holding while I create space to pump foam into my 1972 corner voids?
I had a hole in the drywall in our bathroom that was about 2 in x 5 in that I used Great Stuff to fix. I am impressed with the characteristics of the filler. It filled the hole completely in a few seconds of application. I will warn anyone using it though to make sure you don't fill the hole entirely flush to the wall because this stuff continues expanding after you apply it. I didn't think about that but no big deal really because you can sand it which is exactly what I did, and then applied spacial and paint and it is almost as good as new. For the price this was a heck of a deal because I only used a tiny amount and now am left with nearly a full can. I guess I will have to find somewhere else to use it now. Great product, ... full review https://www.youtube.com/e/ggLAUsiuI_o
Sta-Kool 800 15-year White Elastomeric Roof Coating is Sta-Kool 800 15-year White Elastomeric Roof Coating is a high quality very flexible white acrylic latex roof coating. Coverage is 50-75 sq. ft. per gallon per coat. Two coatings are recommended. This performance product resists cracking and peeling while offering tremendous durability. This long lasting formula forms and excellent highly ...  More + Product Details Close 

Spray Foam Roof Insulation

×