We love the Heng’s rubber roof coating because it is versatile enough to work on the RV roof and protects it from the elements longer than other products do. Plus, it is useful enough to be used in sealing seams and tears. Versatility does matter when shopping around for an RV roof coating. It ensures more uses, meaning more value for the money. That said we don’t need to buy a separate product to perform the tasks. 

I don't know if it's common or uncommon, but installing a layer of rigid foam above your roof sheathing in order to interrupt thermal bridging is always a good idea, and is preferable in all respects to a roof assembly without any rigid foam above the sheathing. If you decide to install rigid foam above the roof sheathing, you shouldn't use closed-cell spray foam under the sheathing; either use open-cell spray foam (which is vapor-permeable) or a fluffy insulation like cellulose, mineral wool, or fiberglass (any of which will allow the roof sheathing to dry to the interior).
I am an Architect in Toronto. I am designing a new roof addition to a row house building. Because of existing conditions and the shape of the new roof. It may be easiest to use closed cell spray foam within the areas of the joists. My question is when spray foam is used in this situation do I need to worry about how the joist members may be thermal bridges? It is not common to provide a little bit of rigid insulation to protect the joist members? The additional layer of outboard insulation will require an extra layer of plywood above the insulation which will add to cost.
They’re the more expensive option than the first one we have discussed above, but they also offer top benefits for the RV owners who want to repair or maintain their RV roof and protect it from UV rays and harsh weather elements. Based on many reviews, these types can offer more durability than the silicone and acrylic types. They can also offer an excellent impact resistance from twigs, leaves and other outer elements.
When it comes to weatherproofing your RV roof, the Flex Seal liquid roof is one of those we’re proud to recommend because it can be applied in all temperatures. It can also protect your camper roof from even the harshest weathers, including rain, snow and wind. With it, you can keep your roof protected from changing temperatures, eventually prolonging its lifespan.
As mentioned above elastomeric coatings can be used to fix almost all types of roofs. Examples of common roof types that will work well with elastomeric coatings include; wood, polyurethane foam, single-ply roofing, modified bitumen, metal roofs, concrete and built-up roofing. If you aren't sure your roof type will work well elastomeric coatings, do not hesitate to contact us. Our experts are always willing to help. https://www.youtube.com/v/ggLAUsiuI_o&feature=youtube_gdata
Spray foam insulation helps lower utility costs because it blocks heat and cold from the outdoors. Recent studies by the U.S. Department of Energy state that around 40 percent of all energy is lost through poor insulation. Spray foam insulation is able to insulate homes at least 50 percent more than traditional insulation products. Spray foam insulation can also provide protection against moisture, which otherwise leads to the unwanted development of mold and mildew. And it can also be used for noise reduction as well. In fact, spray foam is good for homes and buildings in which outdoor noise can be a distraction. https://youtube.com/watch?v=ggLAUsiuI_o&app=desktop
R-value is the term given to thermal resistance to heat flow. The higher the R-value of an insulation product, the more effective the insulation properties. Spray polyurethane foam comes in a range of densities and cel structure. Low density foams are referred to as Open Cel SPF while higher density foams are referred to as Closed Cel foam. 1.8-2 pound polyurethane foam has the highest R-value of readily available spray foam insulation used in homes and buildings.[4]
c) Make sure that the over expanded access is properly removed from the walls. We had a junior cutter taking too much off by bending his saw into the cavity. Look closely at the inside wall corners, and ceiling/wall corners to make sure that the foam is properly removed flush with the studs. If it has not been cut back flush it may lead to uneven drywall finishes . https://youtube.com/e/ggLAUsiuI_o
Steve: If your spray foam installer leaves the vents open, he will be committing the 2nd of the 4 problems I described above. You will most likely have comfort and efficiency problems. You may well have condensation problems. You will be spending a lot of money on a product that likely won't perform as it should. Don't let him leave the vents open. If the installer you've chosen doesn't understand this, you may want to choose someone else. 
“It’s been scientifically proven that the temp of the shingles rises only a couple of degrees when there is an unvented attic compared to a vented attic,” said Garry Barlow, estimator at RetroFoam of Michigan. “If we lived in a southern state it has been proven that the longevity of the shingle did diminish by only one year. In the northern states there was no difference in the life span of the shingles.”
Spray foam insulation, like other insulation, saves on energy costs and lowers utility bills. Studies by the US Department of Energy show that 40% of a home's energy is lost as the result of air infiltration through walls, windows and doorways. Buildings treated with spray foam insulation insulate as much as 50% better than traditional insulation products.

Good article, but it seems like you can chalk up almost all of those problems to the experience level of whomever is spraying the foam. Spray foam isn't an inherently bad product, but it's pretty easy to botch if the hired company is inexperienced. Fiberglass may be foolproof to install, but then again it has a terrible R-Value compared to a good spray foam. People just need to get referrals and do their homework whenever they research a spray foam contractor.

How Much Is Spray Foam Insulation Per Sq Ft


Sean, thanks for jumping in and answering John's questions. About choosing the right foam, I intentionally avoided the open cell vs. closed cell foam debate. I did this partly because it's worthy of an article all by itself, but mainly I didn't include it because, despite all the warnings the two sides issue about the other, I've never personally seen a problem caused by using open cell where they should've used closed cell or vice versa. I'm sure things like that happen; I just haven't seen it yet.
I am building a house in Central Texas (Caldwell). Several builders are cautious about using foam insulation and/or a closed attic. I would like to use both. Here in Texas, heat and humidity (except for the past few years of drought) are a continuing problem. Which type of foam would be the best to use in our home, where should the vapor barrier be or should be use one at all, if we are using fans in the exterior walls to supply fresh air to the house, do we need a vented attic or will it cause more problems than it solve? I have printed out your article and the blogs to give to my contractors and architect, but I would really appreciate your comments on the products being used in my part of the US. 
Sporadic cases of hypersensitivity pneumonitis (HP) have also been reported in workers exposed to isocyanates. The symptoms may seem like the flu, with fever, muscle aches, and headaches. Other symptoms may include a dry cough, chest tightness, and difficult breathing. Individuals with chronic HP often experience progressively more difficult breathing, fatigue, and weight loss. Individuals with acute HP typically develop symptoms 4–6 hours after exposure.[4]
Some states, municipalities and utilities have programs. Check with your coatings manufacturer for further information. As a membership benefit, RCMA provides maintains a database of current information on rebates and tax credits for installing reflective roofs. RCMA’s customized search tool can be used to find the most up-to-date listings of reflective roofing financial incentives available.

How Much Is Attic Spray Foam


once the foam is installed correctly, it is a inert plastic not much different than the foam cushions you sit on. there is not a health rick unless you have off ratio uncured foam that has not mixed properly. the foam is absolutely a health risk in its raw forms before it is mixed and cured. You should not be in the building without proper respirators and eye protection. The spray foam industry should be controlled and regulated by the same standards, testing and inspections that framing ,electrical and plumbing are. until that happens then you will have idiots with spray rigs ruining peoples homes and ruining the market for honest foam contractors that know how to price a job fairly and complete it correctly.
It also has a great waterproofing ability that can shield the roof’s membrane from water and moisture damage. You can also count on the liquid roof coating for its outstanding performance for a wide range of applications and uses. This product can be used at tears and seams as well as in sealing air conditioners and venting systems and anywhere else where rubberized coating is needed. https://m.youtu.be/ggLAUsiuI_o

A: It can be applied in the similar manner that we apply paint. We can use a paint roller to apply it without any hassle and use of special tools. You can also check the specific manual of instructions from the maker for particular directions. You should also check if it requires single or double coating or the use of a primer before its application.
I have never used foam insulation before and this was easy for me to use right out of the box. I had a 4'x8"x8" cavity in my basement that houses a waterline. When the previous homeowner installed this they put no insulation in at all and being that it's an exterior wall in the basement and I live in the Midwest that thing was pushing so much cold air in it was incredibly uncomfortable. Out of the box and job completed in about 5 minutes. Stopped all drafts and created a nice 2" barrier on the wall in which I will install some extra bat insulation over it. 4 stars because the spray isn't very good passed 6-8" from the surface. Make sure you can reach the surface you want to coat. Great for small jobs!
In addition, it's difficult for an inexperienced installer to evenly spread the insulation foam over a surface. Miissing spots can leave holes and gaps for cold air to get through. Proceed with this project yourself only if you're doing a small insulation project -- such as installing foam in a crawl space or around your plumbing. Leave larger projects like the attic, basement or garage to the professional insulation contractors. Insulation professionals have the tools, equipment and background knowledge necessary. Moreover, they know how to accurately price insulation, whereas you could inaccurately budget for a DIY project and end up paying significantly more. Don't take the medical, physical or financial risks that come with pursuing this as a DIY project unless you're absolutely certain you have the skills.
Sean, thanks for jumping in and answering John's questions. About choosing the right foam, I intentionally avoided the open cell vs. closed cell foam debate. I did this partly because it's worthy of an article all by itself, but mainly I didn't include it because, despite all the warnings the two sides issue about the other, I've never personally seen a problem caused by using open cell where they should've used closed cell or vice versa. I'm sure things like that happen; I just haven't seen it yet.
Sean, thanks for jumping in and answering John's questions. About choosing the right foam, I intentionally avoided the open cell vs. closed cell foam debate. I did this partly because it's worthy of an article all by itself, but mainly I didn't include it because, despite all the warnings the two sides issue about the other, I've never personally seen a problem caused by using open cell where they should've used closed cell or vice versa. I'm sure things like that happen; I just haven't seen it yet.
Spray foam insulation, when properly installed is both an air barrier and when closed cell foam is used at the proper depth a vapor barrier!  Before hiring any contractor you should establish the brand of foam being used and verify that with the named manufacture.  Please ask for ESR reports and MSDS sheets on any foam being installed in your home. A couple areas where you might consider spray foam insulation include: http://www.youtube.com/v/ggLAUsiuI_o&feature=youtube_gdata

There is a significant price difference when it comes to using foam insulation to insulate a new versus older home. Spraying insulation inside a newly constructed home is easier because the installation company can ensure the insulation will work effectively and design it for optimum defense against sound, heat transfer and utility costs. Installing spray foam in older homes that contain existing insulation can cost additional time and money -- it is not usually recommended as compared to weatherization or an energy aduit.

Spray Foam Near Me


These coatings contain various types of acrylic polymer, and are typically formulated to help extend the coating’s life and improve durability. Acrylic coatings are available in a number of colors but are most commonly used as white reflective coatings. Thanks to its durability and low cost, many contractors and facility managers believe this to be the best roof coating.
Most flat roofs are not perfectly sloped, causing water to puddle in some areas, in particular around the drains and scuppers. Many roof coatings are not rated or warranted for "ponding water", and thus might fail pre-maturely if exposed to standing water over long periods of time. Serious consideration should be given to the performance and limitations of the coating being selected. Some manufacturers will warranty their coatings including ponding water. Typically, manufacturers for acrylic roof coatings do not include warranties for ponding water, while some polyurethane and silicone roof coatings manufacturers will.
RetroFoam of Michigan has more than 15 years of experience insulating thousands of homes and pole barns across the lower peninsula. We hear a lot of misconceptions about foam insulation and work to make sure we clear up any wrong ideas about foam insulation. Our staff helped us put together this list of misconceptions adding their insights to dispel any misinformation.

However, coating asphalt shingles and built-up composition roofs requires more caution. The National Roofing Contractors Association’s (NRCA) director of technical services has stated "The roofing industry is aware of a number of issues that could have negative consequences for field application of coatings over asphalt shingle roof systems. Anyone considering this type of application should be aware of the concerns so they can weigh them against the benefits claimed in coating product promotional materials."[2]
I don't even want to ask this question but... several years ago we hired a local contractor to spray high density foam on the roof deck and walls of our unfinished 2nd floor. We realized that the job was done poorly and cut an access into the attic space to assess things. We realize now that they spray foamed directly to the chimney (no flashing). The chimney is currently used for a woodstove and DHW venting. The DHW will go away but wood stove will remain. My question is, how bad (unsafe) is this? I have found information on foam exposure to fire but have not been able to find anything about temperature ratings in general (i.e. what happens on prolonged exposure to high temperatures). http://www.youtube.com/e/ggLAUsiuI_o?app=desktop
A unique new event spotlighting the latest design & building processes, products and emerging technologies. This interactive three-day conference & expo is designed to inform and inspire today’s entire building team — innovative and influential architects, engineers, contractors, facility managers, owners and more. Educational sessions will include six separate tracks focused on plumbing, HVACR/mechanical systems, flooring, building envelope, roofing and general contracting. 

If you’re looking for an effective and efficient Elastomeric Roof Coating, you might want to consider the Kool Seal roof coating. This product comes in a 115 fl oz container and is white in color. It is easy to apply and use that it can stick well even in the harshest weather conditions. This product offers maximum clinging to the RV roof despite the temperature. You can also rely on its effectiveness no matter the type of weather.
These coatings are emulsified asphalt and consist of asphalt particles dispersed in water; they utilize clay as the emulsifying component. These coatings also contain many types of organic and/or inorganic fibers and fillers to provide extra strength to the coating. These coatings are available in black, brown, or as a reflective coating when titanium dioxide or aluminum pigments are added. http://youtu.be/ggLAUsiuI_o
Part of that guidance will be explaining that interior, two component foam is applied with the professional using specific personal protective equipment (high-pressure foam is installed while using a respirator, for example). It is encouraged that professionals explain clearly to customers that this equipment, coupled with certain work and engineering practices, including ventilation, is used to minimize exposures to the chemicals used to make SPF during the job. http://www.youtube.com/e/ggLAUsiuI_o
I don't even want to ask this question but... several years ago we hired a local contractor to spray high density foam on the roof deck and walls of our unfinished 2nd floor. We realized that the job was done poorly and cut an access into the attic space to assess things. We realize now that they spray foamed directly to the chimney (no flashing). The chimney is currently used for a woodstove and DHW venting. The DHW will go away but wood stove will remain. My question is, how bad (unsafe) is this? I have found information on foam exposure to fire but have not been able to find anything about temperature ratings in general (i.e. what happens on prolonged exposure to high temperatures).
United Coatings™ Roof Coat Elastomeric Coating is an effective coating for providing long-term reflectivity over a wide range of roofing substrates. The high reflectivity of Roof Coat Elastomeric Coating keeps the roof substrate cool, which not only helps prolong its longevity but also helps save on energy costs. Roof Coat Elastomeric Coating’s rich consistency uniformly covers the textured profile of various substrates, forming a flexible monolithic membrane that provides protection from normal weathering, aging, and ultraviolet exposure.
You've got no argument from me there, Dennis. Getting a good installer if you're going with spray foam is crucial. Many builders or homeowners don't know how to find one, however, and that's where third party inspections come in. Also, even good installers have bad days, but if someone comes in behind them with a measuring probe and a Blower Door, there will be fewer sub-par foam jobs.  
Spray polyurethane foam, or SPF, is the main type of 2-part, closed-cell spray foam used by insulation contractors. Large-scale insulation jobs require special equipment as well as safety gear to protect the installer from chemical fumes during installation. When the foam cures and hardens just several minutes after application, it's completely safe for as long as it stays in place.
If your foam pulled away just a little bit, Jamie, and they were able to fix it with just a little bit of touching up, then it wasn't as bad as the house where I saw this problem. As the last photo above shows, it had pulled away significantly from the studs and rafters, and it was all over the house. This was closed cell foam, and interestingly, it didn't pull away from the horizontal framing members, just the vertical and sloped ones. They did some touch up, but that wasn't enough. I don't know how this one ended up getting resolved. I think maybe the contractor came back and sprayed cellulose on top of the foam.

The insulation at eaves level will leave your loft area comfortable for use and free from condensation. By installing the insulation at rafter level, it keeps the loft void warmer and prevents condensation build-up, which can otherwise occur when increasing insulation at ceiling level. The warmer, drier, cleaner roof space eliminates the risk of pipes and tanks freezing. http://m.youtube.com/embed/ggLAUsiuI_o
During colder months, 2 component foam is very sensitive to temperature variances. Per product instructions, both tank temperatures need to be above 70°F (21°C) for at least 24 hours prior to use. All application surfaces should be clean/dry and above 60°F (16°C) prior to application. Variance outside of the recommended temperature can affect foam yield and performance.
However, coating asphalt shingles and built-up composition roofs requires more caution. The National Roofing Contractors Association’s (NRCA) director of technical services has stated "The roofing industry is aware of a number of issues that could have negative consequences for field application of coatings over asphalt shingle roof systems. Anyone considering this type of application should be aware of the concerns so they can weigh them against the benefits claimed in coating product promotional materials."[2]
I have been looking to have closed cell insulation added through out my attic space. I cant seam to find a installed that wants to install no more than 2 inches, and thats not near my R-valve for South Carolina (Lake Greenwood)please send any advice that will help me to see what installer will perform the correct job. This is a expense that i can only afford to do once. Sandi

Where Can I Purchase Spray Foam Insulation

×