In general, cantilevered steel beams are a nightmare. If part of the steel beam is in contact with exterior temperatures, then it's best if the interior portion of the steel beam is covered on all sides with insulation. This is generally impossible (because the interior portion of the cantilevered beam generally supports a load, meaning that you can't wrap the steel beam in insulation on all sides).
We are turning our roof into an unvented roof assembly by raising the roof and blowing in SPF. We are planning to leave the existing vapor barrier down but remove the fiberglass batting and then adding 6" of SPF in all the cavities, to completely seal and insulate the house. Should we have any concerns about doing it "upside down" and not spraying the foam directly to the underside/sheathing of the roof?

How Much Is Spray Foam Insulation For Attic


My other question was gonna be this. We ripped all the drywall out after Hurricane Harvey and we found some latent termite damage from some time back. One of the common studs in one corner is pretty well eaten to shreds. I was gonna brace it but then I read about more modern framing practices and I read how each stud is a thermal bridge. So now I'm thinking that I won't bother with it because the house hasn't fallen down and the foam might help a little. Unless you say to brace the stud. Then I'll do it, Martin! :) http://www.youtube.com/watch?feature=youtu.be&v=ggLAUsiuI_o
My other question was gonna be this. We ripped all the drywall out after Hurricane Harvey and we found some latent termite damage from some time back. One of the common studs in one corner is pretty well eaten to shreds. I was gonna brace it but then I read about more modern framing practices and I read how each stud is a thermal bridge. So now I'm thinking that I won't bother with it because the house hasn't fallen down and the foam might help a little. Unless you say to brace the stud. Then I'll do it, Martin! :)
Most flat roofs are not perfectly sloped, causing water to puddle in some areas, in particular around the drains and scuppers. Many roof coatings are not rated or warranted for "ponding water", and thus might fail pre-maturely if exposed to standing water over long periods of time. Serious consideration should be given to the performance and limitations of the coating being selected. Some manufacturers will warranty their coatings including ponding water. Typically, manufacturers for acrylic roof coatings do not include warranties for ponding water, while some polyurethane and silicone roof coatings manufacturers will.
In general, cantilevered steel beams are a nightmare. If part of the steel beam is in contact with exterior temperatures, then it's best if the interior portion of the steel beam is covered on all sides with insulation. This is generally impossible (because the interior portion of the cantilevered beam generally supports a load, meaning that you can't wrap the steel beam in insulation on all sides).

How Much Is Spray Foam


The Canadian National Building Code references the CAN/ULC S705.2 National Application Standard which must be followed during all installations of 2lb medium density closed cell polyurethane foam. Every installer of CAN/ULC-S705.1 compliant medium density, spray applied foam must be licensed in order to spray foam and hold valid photo ID issued by their Quality Assurance Program (QAP) provider showing their license is in good standing.

Roof Spray Foam Insulation

×